• SGG-40KVA Dry-Type Isolation Transformer (3-Phase, 380V/220V),SGG-40KVA Dry-Type Isolation Transformer (3-Phase, 380V/220V)
  • SGG-40KVA Dry-Type Isolation Transformer (3-Phase, 380V/220V),SGG-40KVA Dry-Type Isolation Transformer (3-Phase, 380V/220V)
  • SGG-40KVA Dry-Type Isolation Transformer (3-Phase, 380V/220V),SGG-40KVA Dry-Type Isolation Transformer (3-Phase, 380V/220V)
  • SGG-40KVA Dry-Type Isolation Transformer (3-Phase, 380V/220V),SGG-40KVA Dry-Type Isolation Transformer (3-Phase, 380V/220V)
  • SGG-40KVA Dry-Type Isolation Transformer (3-Phase, 380V/220V),SGG-40KVA Dry-Type Isolation Transformer (3-Phase, 380V/220V)
  • SGG-40KVA Dry-Type Isolation Transformer (3-Phase, 380V/220V),SGG-40KVA Dry-Type Isolation Transformer (3-Phase, 380V/220V)
  • SGG-40KVA Dry-Type Isolation Transformer (3-Phase, 380V/220V),SGG-40KVA Dry-Type Isolation Transformer (3-Phase, 380V/220V)
  • SGG-40KVA Dry-Type Isolation Transformer (3-Phase, 380V/220V),SGG-40KVA Dry-Type Isolation Transformer (3-Phase, 380V/220V)
  • SGG-40KVA Dry-Type Isolation Transformer (3-Phase, 380V/220V),SGG-40KVA Dry-Type Isolation Transformer (3-Phase, 380V/220V)
  • SGG-40KVA Dry-Type Isolation Transformer (3-Phase, 380V/220V),SGG-40KVA Dry-Type Isolation Transformer (3-Phase, 380V/220V)
  • SGG-40KVA Dry-Type Isolation Transformer (3-Phase, 380V/220V),SGG-40KVA Dry-Type Isolation Transformer (3-Phase, 380V/220V)
  • SGG-40KVA Dry-Type Isolation Transformer (3-Phase, 380V/220V),SGG-40KVA Dry-Type Isolation Transformer (3-Phase, 380V/220V)

SGG-40KVA Dry-Type Isolation Transformer (3-Phase, 380V/220V)

SGG-40KVA 3-phase dry-type isolation transformer. 380V input, 220V/200V output, ≥95% efficiency, F-class insulation, electrostatic shield >60dB, 20-year design life. For CNC, medical, data center and lab use.
$0.00
Capacity:
SGG-5kVA
SGG-10kVA
SGG-15kVA
SGG-20kVA
SGG-30kVA
SGG-40kVA
SGG-50kVA
SGG-60kVA
SGG-80kVA
SGG-100kVA
  • SGG-40KVA Dry-Type Isolation Transformer (3-Phase, 380V/220V),SGG-40KVA Dry-Type Isolation Transformer (3-Phase, 380V/220V)
  • SGG-40KVA Dry-Type Isolation Transformer (3-Phase, 380V/220V),SGG-40KVA Dry-Type Isolation Transformer (3-Phase, 380V/220V)
  • SGG-40KVA Dry-Type Isolation Transformer (3-Phase, 380V/220V),SGG-40KVA Dry-Type Isolation Transformer (3-Phase, 380V/220V)
  • SGG-40KVA Dry-Type Isolation Transformer (3-Phase, 380V/220V),SGG-40KVA Dry-Type Isolation Transformer (3-Phase, 380V/220V)
  • SGG-40KVA Dry-Type Isolation Transformer (3-Phase, 380V/220V),SGG-40KVA Dry-Type Isolation Transformer (3-Phase, 380V/220V)
  • SGG-40KVA Dry-Type Isolation Transformer (3-Phase, 380V/220V),SGG-40KVA Dry-Type Isolation Transformer (3-Phase, 380V/220V)

Keterangan

The SGG-40KVA is a three-phase dry-type isolation transformer providing complete galvanic separation between primary and secondary windings. Unlike autotransformers, it suppresses common-mode noise, blocks voltage transients and eliminates ground-loop interference. Built with F-class insulation, grain-oriented silicon-steel laminations and an electrostatic shield, it delivers ≥95% efficiency, pure sinusoidal output and a 20-year design life.

Ideal for precision CNC machinery, medical diagnostic equipment, semiconductor fabrication, data centre power conditioning, telecommunications, laboratory instruments and any environment where ground-loop elimination and transient protection are critical.



Key Features

  • Full Galvanic Isolation: No direct electrical path between primary and secondary

  • Electrostatic Shield: >60 dB common-mode noise attenuation

  • High Efficiency: ≥95% with pure sinusoidal output

  • F-Class Insulation (155°C): Temperature rise ≤70°C at full load

  • Dielectric Withstand: AC 3000V / 1 min (primary to secondary)

  • Connection Groups: Δ/Y (recommended), D/d, D/y, Y/y, Y/d, Y/yn

  • Overload Capability: 1.2× rated load

  • Design Life: 20 years, continuous duty

  • Customisable Input: ≤600V

  • Robust Enclosure: IP20 powder-coated steel with castor wheels




Technical Specifications

Item Specification
Model SGG-40KVA
Rated Capacity 40 kVA
Phases 3-Phase
Frequency 50Hz / 60Hz
Connection Group Δ/Y (recommended); D/d; D/y; Y/y; Y/d; Y/yn
Insulation Class Class F (155°C)
Design Life 20 years
Standard GB 19212.14-2012 / EN 61558-2-4
Input Voltage AC 380–415V (customisable ≤600V)
Input THD Tolerance THD ≤5%
Transient Peak Voltage U P-P ≤2000V
Output Voltage AC 200V / 220V (customisable ≤600V)
Waveform Distortion None — pure sine wave
Voltage Regulation ≤1s for input step ≤10V
Common-Mode Noise Attenuation >60 dB (with electrostatic shield)
Efficiency (Isolation) ≥95%
Overload Capacity 1.2× rated load
Temperature Rise ≤70°C (full load, summer ambient)
Noise Level ≤45 dB @ 1m
Withstand Voltage AC 3000V / 1 min (primary-secondary, primary-core, secondary-core)
Insulation Resistance ≥100 MΩ
Protection Degree IP20 (enclosed) / IP00 (bare)
Operating Temperature −10°C to +40°C
Storage Temperature −20°C to +60°C
Operating Humidity 30–90%, non-condensing
Altitude <1000m
Cooling Dry air cooling (natural convection + forced ventilation)
Dimensions (Bare) 480×380×420 mm (L×W×H)
Weight (Bare) 160 kg
Dimensions (With Chassis) 700×500×650 mm (L×W×H)
Weight (With Chassis) 200 kg
Enclosure Material Powder-coated steel
Mobility Swivel castors with locking brakes (chassis model)





Working Principle

An isolation transformer transfers AC energy from primary to secondary exclusively through electromagnetic induction — with no direct electrical connection. The electrostatic shield (Faraday shield) between windings diverts high-frequency common-mode noise and transient surges directly to ground, preventing them from coupling into the secondary circuit.

Installation & Wiring

Select cables and lugs of appropriate cross-section. Maintain adequate clearance on all sides for heat dissipation and maintenance access. Proper grounding is critical — connect chassis ground (PE) and electrostatic shield drain wire to a reliable earth ground. For circuits with zero-sequence current or significant imbalance, neutral conductor cross-section should equal or approach phase conductors. Before wiring, verify no short circuit and insulation resistance ≥100MΩ.

WARNING: Never reverse input/output connections. Never swap phase and neutral. All wiring must be performed with power fully de-energised.

Service Conditions

Indoor use, −5°C to +40°C. Relative humidity <93% (no condensation). Altitude <1000m. Supply voltage approximately sinusoidal (THD ≤5%), three-phase approximately symmetrical. Transient peak grid voltage U P-P ≤2000V. Store in dry, ventilated area, −20°C to +40°C, RH ≤80%.

Daily Maintenance

Dry-type isolation transformers are virtually maintenance-free under normal conditions. In dusty environments, blow out dust from windings and terminals with compressed air (≤2 atm). Check fans, winding insulation for cracks or carbonisation, terminal tightness and grounding integrity (ground resistance ≤4Ω). Record all maintenance activities.

Call to Action (CTA)

Contact us today for a quote or technical datasheet.
WeChat / WhatsApp: +86 13360479957
Website: www.feixiangdapower.com
Email: snow@feixiangdapower.com

HUBUNGI KAMI

Jika Anda memiliki pertanyaan, hubungi kami hari ini! Jangan ragu. Kami berusaha melakukan yang terbaik untuk kepuasan pelanggan kami.
Nama Belakang
E-mail *
Nama Produk & Spesifikasi
Kuantitas
Tinggalkan pesan
Nama Belakang
E-mail *
Nama Produk & Spesifikasi
Kuantitas
Kami menggunakan Kue untuk meningkatkan pengalaman online Anda. Dengan terus menjelajahi situs web ini, kami menganggap Anda menyetujui penggunaan kami atas... Kue .
Message Us